FR | EN
+230 5792 8639
Home Our areas of intervention Private homes Apartment buildings and condominiums Hotels and tourist facilities Pools and aquatic centres Roofs and terraces Golf courses and irrigation networks Public and private water networks Property diagnostics

Apartment buildings and condominiums

Leak detection in common areas and shared networks, without damage.

Common problems

Riser leaks

Riser leaks

Drinking water, wastewater, rainwater

Infiltration in common areas

Infiltration in common areas

Car parks, cellars, halls, plant rooms

Roofs and terraces

Roofs and terraces

Infiltration and waterproofing defects

Shared pools

Shared pools

Basins and related pipework

Outdoor networks

Outdoor networks

Irrigation and supply of green spaces

Our technologies

In an apartment building, the challenge is to trace the problem back to the unit or network of origin without opening up several flats.

Electro-acoustic listening

Electro-acoustic listening

Locates leaks on risers and embedded pipes.

Tracer gas

Tracer gas

Finds leaks on pressurised networks in common areas and basements.

Pipe video inspection

Pipe video inspection

Inspects drainage stacks and wastewater downpipes.

Infrared thermography

Infrared thermography

Shows the extent of water damage from one floor to the next.

Moisture meter

Moisture meter

Maps moisture to trace back to the source.

Fluorescein and UV lamp

Fluorescein and UV lamp

Identifies the flat or fixture causing water damage.

Endoscopic camera

Endoscopic camera

Checks landing ducts and false ceilings without demolition.

Flood and targeted spray tests

Flood and targeted spray tests

Tests façades, terraces and windows for infiltration.

Our interventions

A few real cases handled by our teams, taken from our intervention reports.

Apartment above a shopApartment building

Apartment above a shop

Water damage was affecting the restaurant below an apartment. Pressure testing, an endoscopic camera and targeted spraying revealed water seeping through the shower wall.

Residential complex poolPool

Residential complex pool

The level dropped, then stabilised between the skimmers and the lights. After ruling out any leak on the technical lines, a vacuum-bell test and fluorescein located the defect at the cable gland of a pool light.

Apartment building, top floorRoof

Apartment building, top floor

The ceiling of a 5th-floor apartment was damaged. Spraying the façade cracks and the ridge caused immediate water ingress in the loft, confirming the source.

Residential buildingApartment building

Residential building

Damp was affecting the cellar corridor and a ground-floor ceiling. The investigation ruled out the drain stack and the roof, and pointed the search to the apartment above.